Demo Methods Download
All the Demo Methods described in the VENUS one Programmer's Manual can be downloaded from this section. This offers you the chance to, in addition to the manual, directly see what has been programmed and how it works in simulation mode or on your HAMILTON instrument.
The number in brackets gives you the chapter of Programmer's Manual, where the specific method is described.
IMPORTANT: Depending on the settings during the software installation, not all necessary labware may be activated. To see how to activate needed labware, click here.
Each demo method zip file contains a list showing the used labware in this method.
SW VENUS 4.4IVD/one/two: This Method will move the arm mounted with a UV Lamp from position A to B for a defined time after a defined delay.
SW VENUS one: This method supports NIMBUS pipetting of ARTEL dyes to specified microtiter plate for pipetting performance evaluation.The library that is in this directory must be installed BEFORE method will run (you need to change the install file extension to .msi).
SW VENUS one: This method supports STAR pipetting of ARTEL dyes to specified microtiter plate for pipetting performance evaluation.The library that is in this directory must be installed BEFORE method will run (you need to change the install file extension to .msi).
This NIMBUS method shows how to read a 1D barcode on MTPs, DWPs and NTRs using the NIMBUS labware gripper.
This method shows how to speed up the use of the cLLD detection with 1000ul Channels (11.10).
This method describes using the action editor with 1000ul channels (12.2).
This methods describes how to copy a plate using SMART Steps with 1000ul Channels (12.3).
This methods describes how to copy a plate using SINGLE and Easy Steps with 1000ul Channels (12.4).
This methods copies tubes to plates using SMART Steps with 1000 ul Channels (12.5).
This method describes how to programm a method with results from a excelfile with 1000ul Channels (12.6).
This method copies four 96 well plates into a 384 well plate with CO-RE 96 Probe Head (12.7).
This method supports the use of the CO-RE 384 STP with a serial Dilution (12.8).
This method describes how to build sub-methods and how to invoke a sub-method library for a particular function with 1000ul Channels (12.8).
This method supports the use of the Tube Gripper with 1000ul Channels (16.1).
This method describes the use of the CO-RE Gripper plate handler and the use of arrays with 1000ul Channels (17.2).
This method shows how to read a platebarcode with using the CO-RE Gripper with 1000ul Channels (17.5.2).
This method supports the use of the CR Needle Wash Station for 1000ul Channels (18.3).
This method supports the use of the 96 Wash Station for disposable tips with 96 CORE Head (20.2).
This method supports the use of the 96-384Wash Station for disposable tips with 96 or 384 CORE Head (21.3).
This method describes the use of the BVS Vacuum System with 1000ul Channels (23.3).